Installation Of 6Inch Economic Commercial LED Downlight
The 6inch flat commercial led downlights are suitable for 100-277VAC input with fired-rated junction box, which delivers high lumen of exceptional 80+ CRI and achieve up to 95 lumen per watt. It is available in 3000K,4000K and 5000k ES CCT options with naked wire and E26 base accessaries.
CFL or HID to LED
NOTE: RETROFIT KIT IS VOLTAGE SPECIFIC. VERIFY PROPER VOLTAGE BEFORE INSTALLATION.
Step 1: Remove existing lamp(s).
Step 2: Remove and discard existing reflector.
Step 3: Open board of side of J-box.
Step 4: Locate J-box containing supply wires and cut all supply wires leading to the ballast.(May remove wires of ballast )
Step 5: Twist out conduit knockout.
Step 6: Plug the connector of metal into the junction box.
Step 7: Connect the supply to the LED Driver.
Step 8: Put both clips into top of frame.
Step 9: Push trim into existing mounting frame.
Step 10: Restore power after installation of fixture is completed.
Incandescent to LED
Note:Voltage must be 120v at socket
Step 1: Remove existing lamp(s).
Step 2: Remove and discard existing reflector.
Step 3: Screw E26 to holdbase.
Step 4:Connect yellow plug,wire into slot of holdbase.
Step 5: Use cap cover holdbase.
Step 6: Put both clips into top of frame.
NOTE: RETROFIT KIT IS VOLTAGE SPECIFIC. VERIFY PROPER VOLTAGE BEFORE INSTALLATION.
Step 1: Remove existing lamp(s).
Step 2: Remove and discard existing reflector.
Step 3: Open board of side of J-box.
Step 4: Locate J-box containing supply wires and cut all supply wires leading to the ballast.(May remove wires of ballast )
Step 5: Twist out conduit knockout.
Step 6: Plug the connector of metal into the junction box.
Step 7: Connect the supply to the LED Driver.
Step 8: Put both clips into top of frame.
Step 9: Push trim into existing mounting frame.
Step 10: Restore power after installation of fixture is completed.
Incandescent to LED
Note:Voltage must be 120v at socket
Step 1: Remove existing lamp(s).
Step 2: Remove and discard existing reflector.
Step 3: Screw E26 to holdbase.
Step 4:Connect yellow plug,wire into slot of holdbase.
Step 5: Use cap cover holdbase.
Step 6: Put both clips into top of frame.
Share:
-
Installation Of 6Inch Economic Commercial LED Downlight
-
Installation of Surface Mounted LED Panel Light
-
Installation of LED Troffer
-
Installation Of LED Emergency Backup For 6Inch LED Residential Downlight
-